Metabolomics_QCd (All 1st round QCd variables related to Metabolomics) 179
Name
Label
Description
Unit
DataType
AcOrn_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable AcOrn_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_023.
uM
Real
Ala_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Ala_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_001.
uM
Real
alphaAAA_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable alphaAAA_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_025.
uM
Real
Arg_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Arg_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_002.
uM
Real
Asn_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Asn_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_003.
uM
Real
Asp_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Asp_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_004.
uM
Real
C0_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C0_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=4. 2nd and final QC step on this var created new and final var BIOR_001.
uM
Real
C10_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C10_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.16. 2nd and final QC step on this var created new and final var BIOR_020.
uM
Real
C101_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C101_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.12. 2nd and final QC step on this var created new and final var BIOR_021.
uM
Real
C102_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C102_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_022.
uM
Real
C12_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C12_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.057. 2nd and final QC step on this var created new and final var BIOR_023.
uM
Real
C121_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C121_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.2. 2nd and final QC step on this var created new and final var BIOR_025.
uM
Real
C12DC_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C12DC_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.2. 2nd and final QC step on this var created new and final var BIOR_024.
uM
Real
C14_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C14_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_026.
uM
Real
C141_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C141_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_027.
uM
Real
C141OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C141OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_028.
uM
Real
C142_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C142_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.012. 2nd and final QC step on this var created new and final var BIOR_029.
uM
Real
C142OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C142OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_030.
uM
Real
C16_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C16_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.018. 2nd and final QC step on this var created new and final var BIOR_031.
uM
Real
C161_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C161_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.06. 2nd and final QC step on this var created new and final var BIOR_032.
uM
Real
C161OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C161OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.02. 2nd and final QC step on this var created new and final var BIOR_033.
uM
Real
C162_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C162_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.008. 2nd and final QC step on this var created new and final var BIOR_034.
uM
Real
C162OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C162OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_035.
uM
Real
C16OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C16OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_036.
uM
Real
C181OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C181OH_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=0 LoD=0.023. 2nd and final QC step on this var created new and final var BIOR_039.
uM
Real
C181_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C181_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_038.
uM
Real
C182_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C182_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=0 LoD=0.009. 2nd and final QC step on this var created new and final var BIOR_040.
uM
Real
C18_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C18_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=1 LoD=0.02. 2nd and final QC step on this var created new and final var BIOR_037.
uM
Real
C2_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C2_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.15. 2nd and final QC step on this var created new and final var BIOR_002.
uM
Real
C3_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C3_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.08. 2nd and final QC step on this var created new and final var BIOR_003.
uM
Real
C31_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C31_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_004.
uM
Real
C3DCC4OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C3DCC4OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.09. 2nd and final QC step on this var created new and final var BIOR_014.
uM
Real
C3DCMC5OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C3DCMC5OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.1. 2nd and final QC step on this var created new and final var BIOR_008.
uM
Real
C3OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C3OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.05. 2nd and final QC step on this var created new and final var BIOR_005.
uM
Real
C4_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C4_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_006.
uM
Real
C41_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C41_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_007.
uM
Real
c4OHPro_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable c4OHPro_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_029.
uM
Real
C5_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C5_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_009.
uM
Real
C51_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C51_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_010.
uM
Real
C51DC_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C51DC_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_011.
uM
Real
C5DCC6OH_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C5DCC6OH_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.035. 2nd and final QC step on this var created new and final var BIOR_012.
uM
Real
C5MDC_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C5MDC_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.06. 2nd and final QC step on this var created new and final var BIOR_013.
uM
Real
C61_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C61_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.035. 2nd and final QC step on this var created new and final var BIOR_016.
uM
Real
C6C41DC_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C6C41DC_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.08. 2nd and final QC step on this var created new and final var BIOR_015.
uM
Real
C7DC_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C7DC_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.035. 2nd and final QC step on this var created new and final var BIOR_017.
uM
Real
C8_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C8_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=1 LoD=0.17. 2nd and final QC step on this var created new and final var BIOR_018.
uM
Real
C9_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable C9_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_019.
uM
Real
Cit_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Cit_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_005.
uM
Real
Creatinine_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Creatinine_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_026.
uM
Real
Gln_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Gln_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_006.
uM
Real
Glu_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Glu_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_007.
uM
Real
Gly_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Gly_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_008.
uM
Real
Hexose_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Hexose_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=1 LoD=20. 2nd and final QC step on this var created new and final var BIOR_140.
uM
Real
His_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable His_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_009.
uM
Real
Histamine_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Histamine_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var .
uM
Real
Ile_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Ile_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_010.
uM
Real
Kynurenine_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Kynurenine_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_027.
uM
Real
Leu_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Leu_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_011.
uM
Real
Lys_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Lys_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_012.
uM
Real
lysoPCaC140_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC140_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM; valid=0 LoD=5. 2nd and final QC step on this var created new and final var BIOR_041.
uM
Real
lysoPCaC160_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC160_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.12. 2nd and final QC step on this var created new and final var BIOR_048.
uM
Real
lysoPCaC161_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC161_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM; valid=0 LoD=0.07. 2nd and final QC step on this var created new and final var BIOR_042.
uM
Real
lysoPCaC170_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC170_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM; valid=0 LoD=0.05. 2nd and final QC step on this var created new and final var BIOR_043.
uM
Real
lysoPCaC180_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC180_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM; valid=0 LoD=0.05. 2nd and final QC step on this var created new and final var BIOR_044.
uM
Real
lysoPCaC181_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC181_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.1. 2nd and final QC step on this var created new and final var BIOR_049.
uM
Real
lysoPCaC182_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC182_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM; valid=0 LoD=0.1. 2nd and final QC step on this var created new and final var BIOR_045.
uM
Real
lysoPCaC203_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC203_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.2. 2nd and final QC step on this var created new and final var BIOR_050.
uM
Real
lysoPCaC204_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC204_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM; valid=0 LoD=0.02. 2nd and final QC step on this var created new and final var BIOR_046.
uM
Real
lysoPCaC240_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC240_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=1.3. 2nd and final QC step on this var created new and final var BIOR_051.
uM
Real
lysoPCaC260_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC260_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.5. 2nd and final QC step on this var created new and final var BIOR_052.
uM
Real
lysoPCaC261_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC261_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM; valid=0 LoD=4. 2nd and final QC step on this var created new and final var BIOR_047.
uM
Real
lysoPCaC280_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC280_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.33. 2nd and final QC step on this var created new and final var BIOR_053.
uM
Real
lysoPCaC281_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable lysoPCaC281_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.15. 2nd and final QC step on this var created new and final var BIOR_054.
uM
Real
MetSO_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable MetSO_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_028.
uM
Real
Met_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Met_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_013.
uM
Real
MET_QCd_MultiPairNr
New in R8. For those participants for whom more than one row of data is available data management created arbitrary pair-numbers and assigned them to rows of data belonging to the same participant to allow foraccurate data QC.
Integer
Orn_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Orn_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_014.
uM
Real
PCaaC240_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC240_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.1. 2nd and final QC step on this var created new and final var BIOR_055.
uM
Real
PCaaC260_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC260_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=1.4. 2nd and final QC step on this var created new and final var BIOR_056.
uM
Real
PCaaC281_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC281_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_057.
uM
Real
PCaaC300_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC300_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.2. 2nd and final QC step on this var created new and final var BIOR_058.
uM
Real
PCaaC320_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC320_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_059.
uM
Real
PCaaC321_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC321_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.06. 2nd and final QC step on this var created new and final var BIOR_060.
uM
Real
PCaaC322_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC322_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_061.
uM
Real
PCaaC323_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC323_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.008. 2nd and final QC step on this var created new and final var BIOR_062.
uM
Real
PCaaC341_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC341_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.06. 2nd and final QC step on this var created new and final var BIOR_063.
uM
Real
PCaaC342_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC342_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.1. 2nd and final QC step on this var created new and final var BIOR_064.
uM
Real
PCaaC343_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC343_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_065.
uM
Real
PCaaC344_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC344_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.006. 2nd and final QC step on this var created new and final var BIOR_066.
uM
Real
PCaaC360_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC360_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.2. 2nd and final QC step on this var created new and final var BIOR_067.
uM
Real
PCaaC361_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC361_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_068.
uM
Real
PCaaC362_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC362_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.15. 2nd and final QC step on this var created new and final var BIOR_069.
uM
Real
PCaaC363_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC363_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_070.
uM
Real
PCaaC364_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC364_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_071.
uM
Real
PCaaC365_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC365_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_072.
uM
Real
PCaaC366_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC366_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_073.
uM
Real
PCaaC380_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC380_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.2. 2nd and final QC step on this var created new and final var BIOR_074.
uM
Real
PCaaC381_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC381_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.08. 2nd and final QC step on this var created new and final var BIOR_075.
uM
Real
PCaaC383_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC383_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_076.
uM
Real
PCaaC384_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC384_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_077.
uM
Real
PCaaC385_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC385_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_078.
uM
Real
PCaaC386_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC386_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.02. 2nd and final QC step on this var created new and final var BIOR_079.
uM
Real
PCaaC401_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC401_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.4. 2nd and final QC step on this var created new and final var BIOR_080.
uM
Real
PCaaC402_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC402_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.02. 2nd and final QC step on this var created new and final var BIOR_081.
uM
Real
PCaaC403_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC403_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.006. 2nd and final QC step on this var created new and final var BIOR_082.
uM
Real
PCaaC404_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC404_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_083.
uM
Real
PCaaC405_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC405_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.04. 2nd and final QC step on this var created new and final var BIOR_084.
uM
Real
PCaaC406_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC406_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=1.2. 2nd and final QC step on this var created new and final var BIOR_085.
uM
Real
PCaaC420_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC420_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.05. 2nd and final QC step on this var created new and final var BIOR_086.
uM
Real
PCaaC421_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC421_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.008. 2nd and final QC step on this var created new and final var BIOR_087.
uM
Real
PCaaC422_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC422_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.006. 2nd and final QC step on this var created new and final var BIOR_088.
uM
Real
PCaaC424_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC424_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.006. 2nd and final QC step on this var created new and final var BIOR_089.
uM
Real
PCaaC425_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC425_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.05. 2nd and final QC step on this var created new and final var BIOR_090.
uM
Real
PCaaC426_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaaC426_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.3. 2nd and final QC step on this var created new and final var BIOR_091.
uM
Real
PCaeC300_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC300_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.15. 2nd and final QC step on this var created new and final var BIOR_092.
uM
Real
PCaeC301_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC301_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.02. 2nd and final QC step on this var created new and final var BIOR_093.
uM
Real
PCaeC302_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC302_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.57. 2nd and final QC step on this var created new and final var BIOR_094.
uM
Real
PCaeC321_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC321_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.009. 2nd and final QC step on this var created new and final var BIOR_095.
uM
Real
PCaeC322_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC322_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.02. 2nd and final QC step on this var created new and final var BIOR_096.
uM
Real
PCaeC340_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC340_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.017. 2nd and final QC step on this var created new and final var BIOR_097.
uM
Real
PCaeC341_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC341_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.012. 2nd and final QC step on this var created new and final var BIOR_098.
uM
Real
PCaeC342_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC342_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_099.
uM
Real
PCaeC343_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC343_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_100.
uM
Real
PCaeC360_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC360_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.12. 2nd and final QC step on this var created new and final var BIOR_101.
uM
Real
PCaeC361_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC361_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_102.
uM
Real
PCaeC362_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC362_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_103.
uM
Real
PCaeC363_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC363_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.007. 2nd and final QC step on this var created new and final var BIOR_104.
uM
Real
PCaeC364_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC364_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.013. 2nd and final QC step on this var created new and final var BIOR_105.
uM
Real
PCaeC365_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC365_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.012. 2nd and final QC step on this var created new and final var BIOR_106.
uM
Real
PCaeC380_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC380_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.066. 2nd and final QC step on this var created new and final var BIOR_107.
uM
Real
PCaeC381_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC381_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_108.
uM
Real
PCaeC382_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC382_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.018. 2nd and final QC step on this var created new and final var BIOR_109.
uM
Real
PCaeC383_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC383_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_110.
uM
Real
PCaeC384_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC384_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_111.
uM
Real
PCaeC385_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC385_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_112.
uM
Real
PCaeC386_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC386_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_113.
uM
Real
PCaeC401_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC401_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.06. 2nd and final QC step on this var created new and final var BIOR_114.
uM
Real
PCaeC402_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC402_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_115.
uM
Real
PCaeC403_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC403_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_116.
uM
Real
PCaeC404_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC404_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.1. 2nd and final QC step on this var created new and final var BIOR_117.
uM
Real
PCaeC405_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC405_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.006. 2nd and final QC step on this var created new and final var BIOR_118.
uM
Real
PCaeC406_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC406_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.025. 2nd and final QC step on this var created new and final var BIOR_119.
uM
Real
PCaeC420_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC420_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.4. 2nd and final QC step on this var created new and final var BIOR_120.
uM
Real
PCaeC421_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC421_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_121.
uM
Real
PCaeC422_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC422_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.006. 2nd and final QC step on this var created new and final var BIOR_122.
uM
Real
PCaeC423_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC423_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.006. 2nd and final QC step on this var created new and final var BIOR_123.
uM
Real
PCaeC424_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC424_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.3. 2nd and final QC step on this var created new and final var BIOR_124.
uM
Real
PCaeC425_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC425_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=1.3. 2nd and final QC step on this var created new and final var BIOR_125.
uM
Real
PCaeC443_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC443_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.006. 2nd and final QC step on this var created new and final var BIOR_126.
uM
Real
PCaeC446_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PCaeC446_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.02. 2nd and final QC step on this var created new and final var BIOR_128.
uM
Real
MET_QCd_PCaeC446
New in R8. QCd metabolomics data for the metabolite phosphatidylcholine acyl-alkyl C446 which is part of the group glycerophospholipids. Lab raw variable name: PC ae C44:6. Data obtained from plasma sample using Liquid Chromatography Mass Spectrometry. Relative quantification. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.09
uM
Real
PEA_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable PEA_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_015.
uM
Real
Phe_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Phe_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_016.
uM
Real
MET_QCd_PlateBarcode_New
New in R8. To allow data sharing back with the external lab and simultaneously preventing unauthorised data matching a new random plate barcode was created. A plate barcode is required during data QC since plate-specific pooled sample data is required.
Text
MET_QCd_PlateNr_New
New in R8. To allow data sharing back with the external lab and simultaneously preventing unauthorised data matching a new random plate number was created. A plate number is required during data QC since plate-specific pooled sample data is required.
Integer
Pro_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Pro_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_017.
uM
Real
Sarcosine_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Sarcosine_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_031.
uM
Real
SDMA_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SDMA_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_024.
uM
Real
Serotonin_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Serotonin_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_032.
uM
Real
Ser_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Ser_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_018.
uM
Real
SMC160_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMC160_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.03. 2nd and final QC step on this var created new and final var BIOR_129.
uM
Real
SMC161_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMC161_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_130.
uM
Real
SMC180_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMC180_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.07. 2nd and final QC step on this var created new and final var BIOR_131.
uM
Real
SMC181_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMC181_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_132.
uM
Real
SMC202_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMC202_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.005. 2nd and final QC step on this var created new and final var BIOR_133.
uM
Real
SMC240_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMC240_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.13. 2nd and final QC step on this var created new and final var BIOR_134.
uM
Real
SMC241_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMC241_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.; valid=0 LoD=0.035. 2nd and final QC step on this var created new and final var BIOR_135.
uM
Real
SMOHC141_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMOHC141_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD.;. 2nd and final QC step on this var created new and final var BIOR_136.
uM
Real
SMOHC161_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMOHC161_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=0 LoD=0.012. 2nd and final QC step on this var created new and final var BIOR_137.
uM
Real
SMOHC221_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMOHC221_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=0 LoD=0.015. 2nd and final QC step on this var created new and final var BIOR_138.
uM
Real
SMOHC222_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable SMOHC222_raw. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit). Unit = uM. The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. valid=0 LoD=0.01. 2nd and final QC step on this var created new and final var BIOR_139.
uM
Real
MET_QCd_Special_Wells
New in R8. Coded number for data which does not belong to Fenland participant
Text
Spermidine_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Spermidine_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_033.
uM
Real
t4OHPro_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable t4OHPro_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_030.
uM
Real
Taurine_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Taurine_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_034.
uM
Real
Thr_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Thr_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_019.
uM
Real
Trp_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Trp_raw. All values below detection limit set to 0. -7 = Internal standard undetectable (Concentration unreliable). The _i in the name indicates that missingness was between 0 and 5% and the missing values have been replaced by a random imputed value between 0 and the plate-specific LOD. 2nd and final QC step on this var created new and final var BIOA_020.
uM
Real
Tyr_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Tyr_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_021.
uM
Real
Val_QCstep1
New in R8. 1st step QCd metabolomics data variable for raw variable Val_raw. 0% missingness was found so data is identical to the raw variable data. All values below detection limit set to 0. Invalid flag: missing peak; internal standard too low; signal exceeds quantification limit. Unit = uM. 2nd and final QC step on this var created new and final var BIOA_022.
uM
Real